Description
CUB5TB00 Product Manual
- Preset Timer and Cycle Counter
- Red LED w/Backlighting
- 0.46″ (11.7 mm) High Digits
- 7-Digit Bi-Directional Timing Capability
- 6-Digit Cycle Counting Capability
- 75 mm x 39 mm x 46 mm
- Optional Serial Communication Modules (RS-232 or RS-485)
- Optional Setpoint Card available (Dual Sink* or Relay)
- Optional USB Programming Card available
- Selectable Timer Ranges and Operating Modes
- Elapsed Timer and Preset Timer Functionality
- Display Color Change Capability at Preset Output
- Operates from 9 to 28 VDC Power Source
- NEMA 4X/IP65 Sealed Front Bezel
- WEIGHT: 3.2 oz (100 g)
The CUB5TB00 provides the ultimate in timer flexibility, from its complete user programming to the optional relay output and serial communications capability. The meter functions as an Elapsed Timer or Preset Timer. It also has a built-in Cycle Counter. The display can be toggled either manually or automatically between the Timer and Cycle Counter values. With eight different input operating modes and 18 selectable timer ranges, the meter can be programmed for a wide variety of timing applications.
Software
The CUB5TB00 can be programed with your computer with the Red Lion Controls Crimson 2 Software. Crimson is the only software in the industry that allows you to program panel meters, temperature controllers, HMIs, gateways, the Data Station Plus, Modular Controllers and large displays—all from the same platform. And it offers portability to let you save your configuration files to program other meters and Red Lion devices. This open, intuitive, menu-driven solution guides you quickly through set-up, and delivers performance and capabilities that not only rivals costly competitor software, but exceeds them. No solution is faster, easier or more flexible. At any price.
Specifications
DISPLAY: 8 digit LCD 0.46″ (11.7 mm) high digits
CUB5TB00: Selectable transmissive red or green backlight LED with viewing angle optimized. Display color change capability at preset when using a relay module.
POWER: Input voltage range is +9 to +28 VDC with short circuit and input polarity protection. Must use an RLC model MLPS or a Class 2 or SELV rated power supply.
TIMER DISPLAY: 7-digits
Display Designator: “t” to the left side of the display
Display Range: 0 to 9999999
Overflow/Underflow Indication: Display flashes “t OVEr”
Minimum Digit Resolution: 0.001 Sec.
Maximum Single Digit Resolution: 1 Hr.
Timing Accuracy: ±0.01%
CYCLE COUNTER DISPLAY: 6-digits, may be disabled if not used
Display Designator: “C” to the left side of the display
Display Range: 0 to 999999
Overflow/Underflow Indication: Display flashes “C OVEr”
Maximum Count Rate:
All Count Sources except Input B: 10 Hz
Input B Count Source:
With Timer Input Filter ON: 10 Hz
With Timer Input Filter OFF: 500 Hz
TIMER SIGNAL INPUTS (INP A and INP B):
Logic Inputs, Current Sinking (active low)
Input A:
Internal 7.8KΩ pull-up resistor to +9 to 28 VDC
Trigger levels: VIL = 1.25 V max; VIH = 2.75 V min; VMAX = 28 VDC
Input B:
Internal 10KΩ pull-up resistor to +9 to 28 VDC
Trigger levels: VIL = 0.7 V max; VIH = 2.4 V min; VMAX = 28 VDC
Inputs A and B:
Timer Input Pulse Width: 1 msec min.
Timer Start/Stop Response Time: 1 msec max.
Filter: Software filtering provided for relay or switch contact debounce. Filter enabled or disabled through programming. If enabled, results in 50 msec start/stop response time for successive pulses applied to the same input terminal.
USER INPUT (USR): Programmable function input
Logic Input, Current Sinking (active low)
Internal 10KΩ pull-up resistor to +9 to 28 VDC
Trigger levels: VIL = 0.7 V max; VIH = 2.4 V min; VMAX = 28 VDC
Response Time: 5 msec typ.; 50 msec debounce (activation and release)
MEMORY: Nonvolatile E2PROM memory retains all programming parameters and timer/counter values when power is removed.
CONNECTIONS: Wire clamping screw terminals
Wire Strip Length: 0.3″ (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 3.5 inch-lbs (0.395 N-m) max.
CERTIFICATIONS AND COMPLIANCES:
CE Approved
EN 61326-1 Immunity to Industrial Locations
Emission CISPR 11 Class A
Safety requirements for electrical equipment for measurement, control, and
laboratory use:
EN 61010-1: General Requirements
EN 61010-2-030: Particular Requirements for Testing and Measuring
Circuits
RoHS Compliant
UL Recognized Component: File #E179259
UL Listed: File #E137808
Type 4X Indoor/Outdoor Enclosure rating (Face only)
IP65 Enclosure rating (Face only)
IP20 Enclosure rating (Rear of unit)
Refer to EMC Installation Guidelines for additional information.
CONSTRUCTION: This unit is rated for Type 4X/IP65 requirements for indoor/outdoor use. Installation Category I, Pollution Degree 2. High impact plastic case with clear viewing window. Panel gasket and mounting clip included.
WEIGHT: 3.2 oz (100 g)