G3DN0000 Product Manual

POWER REQUIREMENTS:
Power is supplied to the option card from the main board of your G3 operator
interface.

COMMUNICATIONS:
DeviceNet Port: The DeviceNet port has format and baud rates that are
software programmable up to 500K baud and are digitally isolated. This
port may be configured for various DeviceNet protocols. Check www.
redlion.net/g3 for currently supported protocols.
Isolation from G3DN Communication ports to G3 operator interface:
1000 VDC for 1 minute.

ENVIRONMENTAL CONDITIONS:
Operating Temperature Range: 0 to 50°C
Storage Temperature Range: -20 to 80°C
Operating and Storage Humidity: 80% maximum relative humidity (noncondensing)
from 0 to 50°C.
Altitude: Up to 2000 meters.

CONSTRUCTION: Installation Category I, Pollution Degree 2

GENERAL DESCRIPTION

This is a DeviceNet option card for G3 operator interfaces with isolated high speed communications ports.

The G3 proprietary expansion slot provides a high speed, parallel architecture that extends the functionality and flexibility of the G3 series HMI. This approach allows the G3 series to evolve concurrently with the latest advances in
communications and standards, without sacrificing performance. This high bandwidth channel has significantly greater throughput when compared to the traditional (external) serial gateway approach.

The G3DN option card is easily installed by removing the rear cover of your G3 operator interface, attaching the card using three screws and connecting a single cable. Adding this card gives the operator interface a DeviceNet slave
communications port. It is built with digital isolation to protect the operator interface from the DeviceNet bus and vice versa. It provides the ability to communicate to any DeviceNet master. A connector housing is provided to function as a strain relief for the wires that terminate into the five position connector. The connector is pluggable for easy removal of the G3 operator interface from the DeviceNet bus, without disturbing communications with other devices on the bus.

  • DeviceNet option card for G3 operator interface terminals
  • Configured using Crimson® software (version 2.0 or later)
  • Digitally Isolated DeviceNet Port capable of communicating with any DeviceNet master
  • Powered and Configured from G3 Operator Interface Terminal
  • Installation and Connection hardware Included with Card